Medical Equipment Section (V2)
OID: 2.16.840.1.113883.10.20.22.2.23
LOINCs: #{"46264-8"}
Alias: medical-equipment
Entries Required: N/A
Internal ID: MedicalEquipmentSectionV2
sample2
{
"resourceType" : "Procedure",
"id" : "d6b614bd-04ce-410d-8726-e1fd01dcc72a",
"code" : {
"text" : "Biliary Stent, May 5, 2013",
"coding" : [ {
"code" : "103716009",
"display" : "Stent Placement",
"system" : "http://snomed.info/sct"
} ]
},
"performed" : {
"dateTime" : "2013-05-12"
},
"status" : "completed",
"bodySite" : [ {
"text" : "bile duct",
"coding" : [ {
"code" : "28273000",
"display" : "bile duct",
"system" : "http://snomed.info/sct"
} ]
} ],
"subject" : {
"id" : "patient",
"resourceType" : "Patient"
}
}
C-CDA Equivalent:
<section>
<templateId root="2.16.840.1.113883.10.20.22.2.23" extension="2014-06-09"/>
<templateId root="2.16.840.1.113883.10.20.22.2.23"/>
<code codeSystem="2.16.840.1.113883.6.1"
codeSystemName="http://loinc.org"
displayName="display string"
code="46264-8"/>
<title>Medical Equipment Section (V2)</title>
<text>
<table border="1" width="100%">
<thead>
<tr>
<th>ID</th>
<th>Assigning Auth</th>
<th>Code</th>
<th>Date</th>
</tr>
</thead>
<tbody>
<tr>
<td>~</td>
<td>~</td>
<td>~</td>
<td>05/12/2013 12:00AM UTC</td>
</tr>
</tbody>
</table>
</text>
<entry>
<procedure classCode="PROC" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.22.4.14" extension="2014-06-09"/>
<templateId root="2.16.840.1.113883.10.20.22.4.14"/>
<id root="d6b614bd-04ce-410d-8726-e1fd01dcc72a"/>
<code codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="Stent Placement"
code="103716009">
<originalText>Biliary Stent, May 5, 2013</originalText>
</code>
<statusCode code="completed"/>
<effectiveTime value="20130512"/>
<targetSiteCode codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="bile duct"
code="28273000">
<originalText>bile duct</originalText>
</targetSiteCode>
</procedure>
</entry>
</section>
sample1
{
"resourceType" : "List",
"entry" : [ {
"item" : {
"focalDevice" : [ {
"manipulated" : {
"uri" : "#device"
},
"action" : {
"text" : "Cardiac Pacemaker",
"coding" : [ {
"code" : "14106009",
"display" : "cardiac pacemaker, device (physical object)",
"system" : "http://snomed.info/sct"
} ]
}
} ],
"performed" : {
"dateTime" : "2013-05-12"
},
"resourceType" : "Procedure",
"contained" : [ {
"udiCarrier" : [ {
"deviceIdentifier" : "(01)51022222233336(11)141231(17)150707(10)A213B1(21)1234",
"issuer" : "https://www.fda.gov/"
} ],
"patient" : {
"resourceType" : "Patient",
"id" : "patient"
},
"id" : "device",
"resourceType" : "Device"
} ],
"status" : "completed",
"id" : "d5b614bd-01ce-410d-8726-e1fd01dcc72a",
"code" : {
"text" : "Biliary Stent, May 5, 2013",
"coding" : [ {
"code" : "103716009",
"display" : "Stent Placement",
"system" : "http://snomed.info/sct"
} ]
},
"bodySite" : [ {
"text" : "bile duct",
"coding" : [ {
"code" : "28273000",
"display" : "bile duct",
"system" : "http://snomed.info/sct"
} ]
} ],
"subject" : {
"id" : "patient",
"resourceType" : "Patient"
}
}
} ],
"id" : "3e414708-0e61-4d48-8863-484a2d473a02",
"code" : {
"coding" : [ {
"code" : "40388003",
"display" : "Implant",
"system" : "http://snomed.info/sct"
} ]
},
"status" : "current",
"mode" : "snapshot"
}
C-CDA Equivalent:
<section>
<templateId root="2.16.840.1.113883.10.20.22.2.23" extension="2014-06-09"/>
<templateId root="2.16.840.1.113883.10.20.22.2.23"/>
<code codeSystem="2.16.840.1.113883.6.1"
codeSystemName="http://loinc.org"
displayName="display string"
code="46264-8"/>
<title>Medical Equipment Section (V2)</title>
<text>
<table border="1" width="100%">
<thead>
<tr>
<th>ID</th>
<th>Assigning Auth</th>
<th>Code</th>
<th>Date</th>
</tr>
</thead>
<tbody>
<tr>
<td colspan="4">No records</td>
</tr>
</tbody>
</table>
</text>
<entry>
<organizer classCode="CLUSTER" moodCode="EVN">
<templateId root="2.16.840.1.113883.10.20.22.4.135"/>
<id root="3e414708-0e61-4d48-8863-484a2d473a02"/>
<code codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="Implant"
code="40388003"/>
<statusCode code="completed"/>
<effectiveTime xsi:type="IVL_TS">
<low nullFlavor="UNK"/>
<high nullFlavor="UNK"/>
</effectiveTime>
<component>
<procedure moodCode="EVN" classCode="PROC">
<templateId root="2.16.840.1.113883.10.20.22.4.14" extension="2014-06-09"/>
<templateId root="2.16.840.1.113883.10.20.22.4.14"/>
<id root="d5b614bd-01ce-410d-8726-e1fd01dcc72a"/>
<code codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="Stent Placement"
code="103716009">
<originalText>Biliary Stent, May 5, 2013</originalText>
</code>
<statusCode code="completed"/>
<effectiveTime value="20130512"/>
<targetSiteCode codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="bile duct"
code="28273000">
<originalText>bile duct</originalText>
</targetSiteCode>
<participant typeCode="DEV">
<participantRole classCode="MANU">
<templateId root="2.16.840.1.113883.10.20.22.4.37"/>
<id root="2.16.840.1.113883.3.3719"
extension="(01)51022222233336(11)141231(17)150707(10)A213B1(21)1234"
assigningAuthorityName="https://www.fda.gov/"/>
<id root="913f9c49-dcb5-44e2-087c-ee284f4a00b7"/>
<playingDevice>
<code codeSystem="2.16.840.1.113883.6.96"
codeSystemName="http://snomed.info/sct"
displayName="cardiac pacemaker, device (physical object)"
code="14106009">
<originalText>Cardiac Pacemaker</originalText>
</code>
</playingDevice>
<scopingEntity>
<id root="2.16.840.1.113883.3.3719"/>
</scopingEntity>
</participantRole>
</participant>
</procedure>
</component>
</organizer>
</entry>
</section>